Products

Flame Tamer

Automatic Spot Protection Vertical Mini-Guard - ABC Dry Chemical

Agent Type ABC Dry Chem. ABC Dry Chem. ABC Dry Chem. ABC Dry Chem.
Part # 80250 80501 81001 82001
Agent Capacity 1.13 kg (2.5 lb.) 2.3 kg (5 lb.) 4.5 kg (10 lb.) 9.1 kg (20 lb.)
Ship Weight 1.8 kg (4 lb.) 5 kg (11 lb.) 8.6 kg (19 lb.) 16.3 kg (36 lb.)
Operating Pressure 100 psi (689 kPa) 100 psi (689 kPa) 195 psi (1344 kPa) 195 psi (1344 kPa)
Unit Length 38.7 cm (15.25 in) 43.8 cm (17.25 in) 44.8 cm (17.625 in) 45.4 cm (21.875 in)
Unit Diameter 8.6 cm (3.375 in) 10.8 cm (4.25 in) 15.2 cm (6 in) 19.1 cm (7.5 in)
Max Total Flood Volume 120 cu. ft. 180 cu. ft.  1300 cu.ft. 2184 cu. ft. 
Max Total Flood Height Above Hazard 7.5 ft. 7.5 ft.  13 ft. 14 ft. 
Local Application Coverage Areas 4 ft. x 4 ft. 4 ft. x 6 ft. 10 ft. x 10 ft. 12 ft. x 13 ft.

 

   Maximum Local Application - Height Above Hazard = 4 Feet for all Models

Flame Tamer

Automatic Spot Protection Vertical Mini-Guard - Halotron I

Agent Type Halotron I Halotron I
Part # 87100 87200
Agent Capacity 8.2 kg (18 lb.) 11.3 kg (25 lb.)
Ship Weight 13.2 kg (29 lb.) 19 kg (42 lb.)
Operating Pressure 100 psi (689 kPa) 100 psi (689 kPa)
Unit Length 45.4 cm (17.875 in) 45.4 cm (21.875 in)
Unit Diameter 17.8 cm (7 in) 19.1 cm (7.5 in)
Max Total Flood Volume 500 cu. ft. 700 cu. ft. 
Max Total Flood Height Above Hazard 8 ft. 10 ft. 
Local Application Coverage Areas 4 ft. x 4 ft. 6 ft. x 6 ft.

 

   Maximum Local Application - Height Above Hazard = 4 Feet for all Models

   Requires a heavy duty bracket for mounting (sold seperately)

Flame Tamer

Automatic Spot Protection Horizontal Mini-Guards - ABC Dry Chemical

Agent Type ABC Dry Chem. ABC Dry Chem. ABC Dry Chem. ABC Dry Chem.
Part # 80251 80521 81021 82021
Agent Capacity 1.13 kg (2.5 lb.) 2.3 kg (5 lb.) 4.5 kg (10 lb.) 9.1 kg 920 lb.)
Ship Weight 1.8 kg (4 lb.) 5 kg (11 lb.) 8.6 kg (19 lb.) 16.3 kg (36 lb.)
Operating Pressure 100 psi (689 kPa) 100 psi (689 kPa) 195 psi (1344 kPa) 195 psi (1344 kPa)
Unit Length 36.2 cm (14.25 in) 43.8 cm (17.25 in) 53 cm (20.875 in) 55.6 cm (21.875 in)
Unit Diameter 8.6 cm (3.375 in) 10.8 cm (4.25 in) 15.2 cm (6 in) 19.1 cm (7.5 in)
Max Total Flood Volume 120 cu. ft. 180 cu. ft.  1300 cu.ft. 2184 cu. ft. 
Max Total Flood Height Above Hazard 7.5 ft. 7.5 ft.  13 ft. 14 ft. 
Local Application Coverage Areas 4 ft. x 4 ft. 4 ft. x 6 ft. 10 ft. x 10 ft. 12 ft. x 13 ft.

 

   Maximum Local Application - Height Above Hazard = 4 Feet for all Models

Flame Tamer

Automatic Spot Protection Horizontal Mini-Guard - Halotron I

Agent Type Halotron I Halotron I
Part # 87105 87205
Agent Capacity 8.2 kg (18 lb.) 11.3 kg (25 lb.)
Ship Weight 13.2 kg (29 lb.) 19 kg (42 lb.)
Operating Pressure 100 psi (689 kPa) 100 psi (689 kPa)
Unit Length 45.4 cm (17.875 in) 45.4 cm (21.875 in)
Unit Diameter 17.8 cm (7 in) 19.1 cm (7.5 in)
Max Total Flood Volume 500 cu. ft. 700 cu. ft. 
Max Total Flood Height Above Hazard 8 ft. 10 ft. 
Local Application Coverage Areas 4 ft. x 4 ft. 6 ft. x 6 ft.
Mounting Bracket 700228 700229

 

   Maximum Local Application - Height Above Hazard = 4 Feet for all Models

   Requires a heavy duty bracket for mounting (sold seperately)